| Model |
Engine HP |
Typical Generating Set Output 415V, 50Hz |
| |
|
Heat Exchanger
Cooled Set kVA |
Radiator
Cooled Set kVA |
| G2 Series |
| GD2V6 |
98 |
81 |
75 |
| GD2V8 |
130 |
110 |
100 |
| GD2V12 |
184 |
150 |
150 |
| TBGD2V6 |
156 |
125 |
125 |
| TBGD2V8 |
207 |
180 |
170 |
| TBGD2V12 |
321 |
275 |
250 |
| G4 Series |
| GD4 V12 |
225 |
215 |
200 |
| TBDG4 V12 |
544 |
450 |
430 |
|
GD2/GD4 - Naturally Aspirated Engines.TBDG - Turbo Charged after cooled engines with air to water after cooler.
- The ratings are in accordance with ISO 3046; DIN 6271 and BS 5514 under following conditions. Air
temperature
270C, Air pressure 100kPA, Relative humidity 60%, 10% overload permitted for 1 hour in every 12 hours.
- The power outputs indicated are based for operation on Natural Gas. These outputs are subject to
a tolerance of +/-5%. For operation on any other fuel, nearest Greaves office may please be contacted.
In view of continues improvement the specifications are subject to change without notice.
|